Salinity Probe Calibration Salinity Probe Calibration Procedure:
If a hand held meter is not available you can remove the probe and dip it into a known calibrated solution. This can be obtained from Spectra. ![]() Emergency Operation: In the event of a salinity probe failure the MPC- Control will come up with a error code. "Salinity Probe Failed". This will render the control inoperative. To make the control temporarily operative you may remove the plug connector from the probe and place into a small quantity of product water. Use a nonmetallic container. Restart the system. If you receive a high salinity code you have the choice of adding some salt water to the container or adjusting the control calibration. Locate the calibration screw on the control board, which is located 3/4" below the salinity probe female plug on the MPC board. Rotate clockwise several turns. Note: this is a temporary repair that will destroy the probe cable. After several days in this mode you may have to remove the connector, strip and spread the wires and replace in the water. |
|